Bird Termaline 6151 Wattmeter RF Load (New) 2-2000 MHz (Uses Model 43 Elements)
Bird Termaline(c) 6151 Wattmeter and RF Load. 2-2000 MHz. The 6151 uses the standard Model 43 elements. Scales for 0.25, 0.5, 1.0, 5, 10, 25, 50, 100 Watts (scales also valid for 250, 500, etc. Watts intermittent duty). New old stock, perfect condition, specifications are guaranteed for 90 days. Bird QC connector Type N(F) input connector, 50 Ohms. Rated for 100 Watts continuous, can be used at higher power as long as the RF Load is not allowed to overheat. I've tested elements to 500 Watts in short bursts with no problems and no noticeable heating. Accuracy is +/- 5% fs to 1 GHz, +/- 8% fs from 1 GHz to 2 GHz. Detachable meter head for remote operation. This is a discontinued Bird product and a rare find in new condition. Elements are not inlcuded.
|
|
|
|
| |
|
Bird Termaline 6151 Wattmeter RF Load (Used) 2-2000 MHz (Uses Model 43 Elements)
Bird Termaline(c) 6151 Wattmeter and RF Load. 2-2000 MHz. The 6151 uses the standard Model 43 elements. Scales for 0.25, 0.5, 1.0, 5, 10, 25, 50, 100 Watts (scales also valid for 250, 500, etc. Watts intermittent duty). New old stock, perfect condition, specifications are guaranteed for 90 days. Bird QC connector Type N(F) input connector, 50 Ohms. Rated for 100 Watts continuous, can be used at higher power as long as the RF Load is not allowed to overheat. I've tested elements to 500 Watts in short bursts with no problems and no noticeable heating. Accuracy is +/- 5% fs to 1 GHz, +/- 8% fs from 1 GHz to 2 GHz. Detachable meter head for remote operation. This is a discontinued Bird product and a rare find in excellent condition. Elements are not inlcuded.
|
|
|
|
| |
|
Bird 8892D300 Termaline RF Load (New and Used) 2500 Watts DC to 2.5 GHz 1 5/8 EIA Flange
8892D-300 Termaline® RF Coaxial Termination
2.5 kW, Oil-Coolled, 1 5/8" EIA Flange Connector
D Series is especially tuned for low VSWR 470-860 MHz for DTV
- Rugged load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation to 2.5KW.
- Simple but rugged design minimizes maintenance requirements.
- Ambient Temperature Range: -40°C to +45°C
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max., 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 GHz 1.3 max., 470-860 1.065 max.
- Impedance: 50 ohms nominal
- Load Coolant: 2.9 gal. (11 liters) silicone oil
- Nominal Size: 23 1/8" L x 7" W x 17 3/16" H, (587 mm x 178 mm x 437 mm)
- Operating Position: Horizontal Only
- Power Rating: 2500 W continuous
- Weight: 57 lbs. (26 kg)
The Model 8890-300 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz. As shown except with 1 5/8 EIA Flange Input Connector Select New or Used Below.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8892-300 Termaline RF Load (New) w/Thermoswitch Option 2500 Watts DC to 2.5 GHz 1-5/8" Flanged Connector 5000 Watts w/BA-300 Optional Blower Assembly
8892-300 Termaline® RF Coaxial Termination
2.5 kW, Oil-Cooled, 1-5/8" Flange Connector
- Rugged load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation to 2.5KW.
- Overload thermoswitch P/N 8890-008 is included Free.
- 5000W Continuous With optional BA-300 blower assembly.
- Simple but rugged design minimizes maintenance requirements.
- Ambient Temperature Range: -40°C to +45°C
- Connector: 1-5/8" Flanged Connector
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max., 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 GHz 1.3 max
- Impedance: 50 ohms nominal
- Load Coolant: 2.9 gal. (11 liters) silicone oil
- Nominal Size: 23 1/8" L x 7" W x 17 3/16" H, (587 mm x 178 mm x 437 mm)
- Operating Position: Horizontal Only
- Power Rating: 2500 W continuous
- Weight: 57 lbs. (26 kg)
The Model 8892-300 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8890-300 Termaline RF Load (New) 2500 Watts DC to 2.5 GHz 5000 Watts w/BA-300 Optional Blower Assembly
8890-300 Termaline® RF Coaxial Termination
2.5 kW, Oil-Cooled, LC Female or Type N Female
- Rugged load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation to 2.5KW.
- Shipped with LC connector installed. Compatible with all Bird QC connectors.
- Simple but rugged design minimizes maintenance requirements.
- Ambient Temperature Range: -40°C to +45°C
- Connector: QC-LC(F) or Type N(F)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max., 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 GHz 1.3 max
- Impedance: 50 ohms nominal
- Load Coolant: 2.9 gal. (11 liters) silicone oil
- Nominal Size: 23 1/8" L x 7" W x 17 3/16" H, (587 mm x 178 mm x 437 mm)
- Operating Position: Horizontal Only
- Power Rating: 2500 W continuous
- Weight: 57 lbs. (26 kg)
The Model 8890-300 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8890-300 Termaline RF Load 2500W - 5000W (Used/New) 2500 Watts up to 2.5 GHz (5000W w/BA-300 option)
8890-300 Termaline® RF Coaxial Termination
Used in New Condition
2.5 kW (5 kW w/BA-300 Option)
LC Female or Type N Female Bird QC Connectors
- Rugged load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation to 2.5KW.
- Shipped with LC connector installed. Compatible with all Bird QC connectors.
- Simple but rugged design minimizes maintenance requirements.
- Ambient Temperature Range: -40°C to +45°C
- Connector: QC-LC(F) or Type N(F)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max., 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 GHz 1.3 max
- Impedance: 50 ohms nominal
- Load Coolant: 2.9 gal. (11 liters) silicone oil
- Nominal Size: 23 1/8" L x 7" W x 17 3/16" H, (587 mm x 178 mm x 437 mm)
- Operating Position: Horizontal Only
- Power Rating: 2500 Watts continuous (5000 Watts continuous w/BA-300 option)
- Weight: 57 lbs. (26 kg) (72 lbs w/BA-300 option)
The Model 8890-300 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz.
Used in New condition
Select BA-300 Blower Assembly below for 5 KW Continuous Operation.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8895-300 Termaline RF Load (New) 2500 Watts DC to 2.5 GHz 1-5/8" EIA, Unflanged
8895-300 Termaline® RF Coaxial Termination
2.5 kW, Oil-Cooled 1-5/8" Unflanged Connector
- Rugged load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation to 2.5KW.
- Simple but rugged design minimizes maintenance requirements.
- Ambient Temperature Range: -40°C to +45°C
- Connector: 1-5/8" EIA, Unflanged
- Finish: Gray powder coat
- DC - 1 GHz @ 1.1 max., 1 GHz - 2 GHz @ 1.25 max., 2 GHz - 2.4 GHz @ 1.3 max
- Impedance: 50 ohms nominal
- Load Coolant: 2.9 gal. (11 liters) silicone oil
- Nominal Size: 23 1/8" L x 7" W x 17 3/16" H, (587 mm x 178 mm x 437 mm)
- Operating Position: Horizontal Only
- Power Rating: 2500 W continuous
- Weight: 57 lbs. (26 kg)
The Model 8895-300 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird BA-300-115 Blower Assembly for Bird RF Loads 1 KW to 2.5 KW (Used) Doubles The Continuous Power Rating
Bird Blower Assembly Doubles RF Load Ratings
BA Series Blower Assemblies
The BA-300 Series consists of two high frequency fans, with vertical side baffles to direct air over the loads radiator fins. The blower doubles the normal RF input rating of the installed load, e.g. a 2.5kW load can dissipate 5 kW.
- Dual Fan Blower Assembly
- Increases Bird RF Load Continuous Rating 2x
- 115 VAC (BA-300-230 for 230 VAC)
- For 8890 Series RF Loads and 8329 Attenuators
- Rugged and Reliable
- Easy to Use
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8860 Termaline RF Load (New or Used) 1.5 KW DC-2 GHz
8860 Termaline® RF Coaxial Termination
1500 Watts Oil-Cooled, LC Female or Type N(F)
Compact, about 1/2 the Weight and size of the 2.5 kW loads
- Rugged load for high power base station RF testing up to 2 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation up to 1500W full rated power.
- Shipped with LC connector installed or Type N(F). Compatible with all Bird QC connectors.
- Simple but rugged design minimizes maintenance requirements.
The Model 8860 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically nonreflective termination for testing and adjusting transmitters under nonradiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2 GHz. Used in Like New Condition
Product Specifications:
- Ambient Temperature Range: -40°C to +45°C
- Connector: QC-LC(F)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1GHz to 2 GHz at 1.25 max.
- Load Coolant: 1.5 gal. (5.68 liters) silcone oil
- Nominal Size: 17 1/8" L x 7 1/2" W x 13 1/8" H, (445 mm x 184 mm x 333 mm)
- Operating Position: Horizontal only
- Power Rating: 1500 W continuous
- Weight: 30 lbs. (12.6 kg)
Select New or Used Below
Operating Manual and Specifications
|
|
|
|
| |
|
Bird 8833-300 Termaline RF Load (used) 1000-1500 Watts DC to 2.4 GHz
8833-300 Bird Termaline® RF Coaxial Termination
1000 Watts, Oil-Cooled, LC Female or Type N Female
- Rugged load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation up to 1000W full rated power.
- Shipped with LC connector installed. Compatible with all Bird QC connectors.
- Simple but rugged design minimizes maintenance requirements.
- Ambient Temperature Range: -40°C to +45°C
- Connector: QC-LC(F) or Type N(F)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max., 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 GHz 1.3 max
- Impedance: 50 ohms nominal
- Load Coolant: 2.9 gal. (11 liters) silicone oil
- Nominal Size: 23 1/8" L x 7" W x 17 3/16" H, (587 mm x 178 mm x 437 mm)
- Operating Position: Horizontal Only
- Power Rating: 1000 W continuous, 1500 Watts 50% Cycle
- Weight: 57 lbs. (26 kg)
The Model 8833-300 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically nonreflective termination for testing and adjusting transmitters under nonradiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz. Similar to Bird 8890-300 but 1000 Watt continuous rating.
Used in excellent condition.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8251D Termaline RF Load 1 KW (New) DC-2500 MHz 1 KW RF Load Digital Broadcast 1-5/8" EIA Connector
8251D Bird Termaline® RF Coaxial Termination
1 kW Continuous Duty, Oil-Cooled, DC-2.4 GHz
Digital Broadcast VSWR = 1.056 max., 470-860 MHz
New Old Stock - New In Origianl Packing with Manuals
Regular Price New is $1118.
- Rugged portable Bench load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted convection cooling for safe, continuous operation up to 1000W full rated power.
- Shipped with 1-5/8" EIA Flange connector installed
- Adapter to N (F) available
- Adapter to DIN 7/16 (F) available
- Low-profile housing with handle and rubber feet for trouble-free operation in the most demanding environments.
- Ambient Temperature Range: -40°C to +45°C
- Connector: 1-5/8" EIA Flange, N(F) Adapters Available (Select Options Below)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 at 1.3 max. (VSWR = 1.056 max., 470-860 MHz)
- Load Coolant: 1.1 gal. (4.1 liters) silcon oil
- Nominal Size: 17 29/32" L x 8 1/2" H x 5 15/16" W, (455 mm x 216 mm x 151 mm)
- Operating Position: Horizontal only
- Power Rating: 1000 W continuous
- Weight: 25 lbs, 8 oz. (11.5 kg)
The Model 8251 TERMALINE® Load Resistor is a portable, self-contained general purpose 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically nonreflective termination for testing and adjusting transmitters under nonradiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz.
New in Box with Manuals
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 25-T-MN Termaline RF Load DC- 4GHz (New and Used)
Bird Electronic 50 Ohm RF load, 25 Watts continuous, DC - 4GHz. Type N male coaxial connector. DC to 4 GHz. Used in excellent condition. Select new or used below.
|
|
|
|
| |
|
Bird 8251 Termaline RF Load 1 KW DC-2500 MHz 1 KW RF Load (New or Used)
8251 Bird Termaline® RF Coaxial Termination
1 kW Continuous Duty, Oil-Cooled
Used in new condition or New, select in options below.
- Rugged portable Bench load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted convection cooling for safe, continuous operation up to 1000W full rated power.
- Shipped with LC or Type N connector installed.
- Low-profile housing with handle and rubber feet for trouble-free operation in the most demanding environments.
- Ambient Temperature Range: -40°C to +45°C
- Connector: QC type (Female LC normally supplied, and Female N normally supplied unmounted)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 at 1.3 max.
- Load Coolant: 1.1 gal. (4.1 liters) silicon oil
- Nominal Size: 17 29/32" L x 8 1/2" H x 5 15/16" W, (455 mm x 216 mm x 151 mm)
- Operating Position: Horizontal only
- Power Rating: 1000 W continuous
- Weight: 25 lbs, 8 oz. (11.5 kg)
The Model 8251 TERMALINE® Load Resistor is a portable, self-contained general purpose 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz. Select New Or Used Below.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8201 Termaline RF Load 500 Watt DC-2500 MHz (Used)
Bird 8201 Termaline® RF Coaxial Termination
500 Watt, Oil-Cooled, N Female Connector
- Rugged portable Bench load for medium power base station RF testing up to 2.5 GHz.
- Oil-assisted convection cooling for safe, continuous operation up to 500W full rated power.
- Quick Change (QC) connectors to minimize the need for adaptors when making critical measurements.
- Low-profile housing with handle and rubber feet for trouble-free operation in the most demanding environments.
- Ambient Temperature: -40°C to +45°C
- Connector: QC type (Female N normally supplied)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1 GHz to 2.5 GHz at 1.25 max
- Load Coolant: 0.9 gal. (3.42 liters) refined mineral oil
- Nominal Size: 16 13/16" L x 8 1/2" H x 5 15/16" W, (427 mm x 216 mm x 151 mm)
- Operating Position: Horizontal only
- Power Rating: 500 W continuous
- Weight: 21 lbs. (9.5 kg)
The Model 8201 TERMALINE® Load Resistor is a portable, self-contained general purpose 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.5 GHz.
Select New or Used Below.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8401 Termaline RF Load 600 Watts DC-3000 MHzB Select New or Used
Bird 8401 Termaline® RF Coaxial Termination
600 Watt, Oil-Cooled, N Female Connector
- Rugged portable Bench load for medium power base station RF testing up to 2.5 GHz.
- Oil-assisted convection cooling for safe, continuous operation up to 600W full rated power.
- Quick Change (QC) connectors to minimize the need for adaptors when making critical measurements.
- Low-profile housing with handle and rubber feet for trouble-free operation in the most demanding environments.
- Ambient Temperature: -40°C to +45°C
- Connector: QC type (Female N normally supplied)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC-1 GHz at 1.1 max, 1-2.8 GHz at 1.2 max., 2.8-3 GHz at 1.3 max
- Load Coolant: 0.7 gal. (2.73 liters) refined mineral oil
- Nominal Size: 16 13/16" H x 8 1/2" W x 5 15/16" D, (427 mm x 216 mm x 151 mm)
- Operating Position: Horizontal only
- Power Rating: 600 W continuous
- Weight: 20 lbs. (9.1 kg)
The Model 8401 TERMALINE® Load Resistor is a portable, self-contained general purpose 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.5 GHz.
Select New or Used below.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8402 Termaline RF Load 600 Watts DC-3000 MHz
Same specificatons as Bird 8401 (see above item) except that the factory supplied input connector was QC Type C(F). This item is shipped with a Type N(F) connector installed unless otherwise requested.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8404 Termaline RF Load 600 Watts DC-3000 MHz
Same specificatons as Bird 8401 (see above item 8401) except factory supplied Type N(M) to Type N(M) adapter was shipped with the item. This item is shipped with a Type N(F) connector installed.
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8080 Bird 8000 Termaline RF Load 25 Watts 25-T-MN
25 Watt 50 ohm Termaline RF Load, used in excellent condition. This is the Bird RF load that fits inside a Bird CC-1(3) leather case. DC to 4 GHz. Discontinued, limited quantity.
|
|
|
|
| |
|
Bird 8085 Termaline RF Load 50 Watts
50 Watts, 50 Ohms DC-3 GHz. Type N(M) input connector. Used in good condition. Discontinued, limited quantity.
|
|
|
|
| |
|
Bird 50-T-MN Termaline RF Load DC- 4GHz (New and Used)
Bird Electronic 50 Ohm RF load, 50 Watts continuous, DC - 4GHz. Type N male coaxial connector. DC to 4 GHz. Used in excellent condition. Select Used or New Below.
|
|
|
|
| |
|
Bird 75-T-FN Termaline RF Load DC- 4GHz N(F) (New and Used)
Bird Electronic 50 Ohm RF load, 75 Watts continuous, DC - 4GHz. Type N(F) coaxial connector. DC to 4 GHz. Similar to shown except Input connector is Type N(F). Used is new old stock in original packing.
|
|
|
|
| |
|
Bird 100-T-FN Termaline RF Load 100 Watts (NOS)
Bird RF Load 100 Watts to DC-2.4 GHz. Continuous rating. Type N female connector, 50 Ohms. New condition. Also, select New or NOS below. NOS is new old stock. Similar to picture but with Type N(F) Connector.
Specifications
- Power Rating (Watts): 100
- Frequency Range VSWR: DC to 1 GHz at 1.10:1 max, 1 GHz to 2.4 GHz at 1.25:1 max.
- Operating Temperature (°C): -40°C to +40°C
- Product Type: Dry (Convection-Cooled)
- Operating Position: Vertical
- Connector(s): N-Type, BNC, 7/16 DIN
- Finish: Black Anodized fins. Silver or Tri-Alloy Plated connector
- Nominal Size [inches (mm)]: (N(F)): 6.4" L x 2.6" W x 7.0" H, (162.6 mm x 66.1 mm x 172.8 mm)
- Weight [lbs (kg)]: 3.6 lbs. (1.64 kg)
|
|
|
|
| |
|
Bird 100-ST-ME 7/16 DIN Termaline RF Load (Used) 100 Watts 0-4 GHz
Bird 100-ST-ME 1/16 DIN RF Load
- 100 Watt, Convection-Cooled Dry
- 7/16 DIN Male
- Rugged Reliability provides years of trouble free use.
- Compact size, tapped mounting holes for fixed installations
Bird's RF terminations are world renowned for their high-quality, robust construction and conservative power ratings. The use of non-magnetic materials and plating provide safety when used in high magnetic fields such as MRI.
Product Specifications:
- Ambient Temperature: -40°C to +40°C
- Connector: 7/16 DIN Male
- Coolant: Dry (Convection cooled)
- Finish: Black anodized fins.
- Frequency Range and VSWR: DC to 1 GHz at 1.10:1 max, 1 GHz to 4 GHz at 1.25:1 max.
- Nominal Size: 6.95" L x 2.75" W x 2.75" H (174 mm x 69.9 mm x 69.9 mm)
- Operating Position: Any
- Power Rating: 100 Watts
- Weight: 2.62 lbs. (1.20 kg)
Select New or Used below.
|
|
|
|
| |
|
Bird 150-WT-FN Termaline RF Load 150 Watts (Used) 150 Watt DC-2.4 GHz
150 Watt, Convection-Cooled Dry
Bird's RF terminations are world renowned for their high-quailty, robust construction and conservative power ratings. The use of non-magnetic materials and plating provide safety when used in high magnetic fields such as MRI.
- Rugged Reliability provides years of trouble free use
- Ultra-Compact size
- Tapped mounting holes for fixed installations
- Optionally available as a Calibrated Mismatch Load
Specifications:
- Power Rating (Watts) 150
- Frequency Range and VSWR DC to 1 GHz at 1.10:1 max., 1 GHz to 2.4 GHz at 1.25:1 max
- Impedance (Ω) 50
- Product Type Dry (Convection-Cooled)
- Ambient Temp Range [°C (°F)] -40°C to +40°C
- Connector N-Type (BNC, TNC, 7/16 DIN, QC Option)
- Finish Black Anodized. Silver or Tri-Alloy Plated connectors
- Weight [lbs (kg)] 2.5 lbs. (1.13 kg)
Used in new condition, or select new below.
|
|
|
|
| |
|
Bird 8065 DC-2.4 GHz Termaline RF Load 160 Watts
160 Watts DC - 2.4 GHz. Continuous power rating is 160 Watts. Type N female QC connector, 50 Ohms. Used in excellent condition. Similar to item shown. Appx 7Lx5Wx3H, 4 lbs.
|
|
|
|
| |
|
Bird 8164 Termaline RF Load 100 Watts 0-2.5 GHz
100 Watts Continuous, 0-2.5 GHz. QC Type N(F) or N(M) input connectors. Bird packages this 100W RF load with several of the their wattmeter kits. In excellent condition. Similar to item shown.
|
|
|
|
| |
|
Bird 300-T Termaline RF Load 300 Watts DC-2.4 GHz
300-T Series Bird's RF terminations are world renowned for their high-quailty, robust construction and conservative power ratings. The use of non-magnetic materials and plating provide safety when used in high magnetic fields such as MRI. No fluids or maintenance required.
- 300 Watt, Convection-Cooled Dry
- Wide variety of connectors - N, TNC, BNC, 7/16 DIN (Type N(f) Standard)
- Rugged Reliability provides years of trouble free use.
- Compact size, easily transportable benchtop design
- Coolant Dry
- DC to 1 GHz at 1.10:1 max, 1 GHz to 2.4 GHz at 1.25:1 max.
Bird's RF terminations are world renowned for their high-quailty, robust construction and conservative power ratings. The use of non-magnetic materials and plating provide safety when used in high magnetic fields such as MRI.
Select New our Used Below
Bird Specifications
|
|
|
|
| |
|
Bird 8166 Termaline RF Load (Used) 150 Watts 0-2.5 GHz
150 Watts Continuous, 0-2.5 GHz. QC Type N female input. This RF load is similar to the Bird 150-ST. At a little over 5 lbs this load is a heavy duty, serious RF Load that can be used into the microwave frequencies. In excellent condition with some minor scratches in the paint.
|
|
|
|
| |
|
Bird 8141 Termaline RF Load 250 Watts DC-2.5 GHz
One of the most popular Bird RF loads, compact and handles high power. Termaline 50 Ohm 250 Watt continuous RF Load DC-2.5 GHz. Used in excellent condition. Tyne N female input. 250 Watt continuous, 300 Watts 10 minutes.
|
|
|
|
| |
|
Bird 8135 Termaline RF Load 150 Watt 0-1000 MHz
Model 8135 is rated at 150 watts continuous with an impedance of 50 ohms. It has a Type N(F) input connector. 0-1000 MHz. Used, in excellent condition.
|
|
|
|
| |
|
Bird 8173 Termaline RF Load DC-1 GHz 300 Watts
300 Watt Continuous dury 50 Ohm dummy load. DC-1 GHz, type N female connector. Used in new condition. Type N(F) input connector.
|
|
|
|
| |
|
Bird 8865SC13 1 KW Termaline® RF Coaxial Termination 50 Ohm RF Load 1 KW Continuous Duty
8865SC13 Termaline® RF Coaxial Termination
1 kW, 13.56 MHz Ultra Stable, Oil-Cooled
Tested to 450 MHz less than 1:1.2 SWR
* Ultra stable, oil-dielectric RF load for semiconductor processing applications.
* <0.1dB total change in VSWR from 0 to 100% rated power at 13.56 MHz
* Passive design, No warm-up time required. Homogeneous RF design provides long-term repeatability
* Ultra-low VSWR - typically <1.05:1 at process critical frequencies
*Tested to 450 MHz less than 1:1.2 SWR
The Model 8865SC13 is an ultra-stable, low VSWR load for quick and precise measurement of generator power output when used with precision power sensors such as the Bird 4020 series. This load not only provides low VSWR, but also less than 0.1 dB total change in VSWR at process-critical frequencies. There is no need for load warm-up or risk of repeatability due to calibration “drift” over different lengths of time. This minimizes errors associated with the calibration process which controls one of the more critical variables within the etch process. Length 18", height 13", width 8", weight 30 lbs.
Designed for the semiconductor industry this 1 KW also serves well as a general purpose RF load for HF, VHF, and UHF frequecies. Tested to 450 MHZ with an SWR of 1:1.21. Compact vertical design with a small footprint. Tyoe N, LC, or UHF female input connector (speicify when ordering).
Used in excellent condition,
or select New below, new items are in stock.
Bird Electronic Data Sheet
|
|
|
|
| |
|
Bird 8251D Termaline RF Load 1 KW DC-2500 MHz 1 KW RF Load (NEW) Digital Broadcast VSWR = 1.056 max 470-860 MHz
1 kW, Oil-Cooled Digital Broadcast Model 8251D 7/8 EIA Swivel Flange Connector
New Old Stock, in sealed factory packing with manuals
The 8251 Series are portable, self-contained general purpose 50 ohm coaxial transmission line terminations requiring no outside power source or additional equipment. The loads are Oil-assisted convection cooling for safe, continuous operation up to 1000W full rated power. They provide accurate, dependable, and practically nonreflective termination for testing and adjusting transmitters under nonradiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor.
Digital Broadcast Model with 7/8 EIA Swivel Flange (M) Connector.
VSWR = 1.056 max from 470-860 MHz
Bird Specifications and Manual
|
|
|
|
| |
|
Bird 8862 Termaline RF Load 1 5/8 EIA Flange (New or Used) 1.5 KW DC-2 GHz
8862 Termaline® RF Coaxial Termination
1500 Watts Oil-Cooled
Compact, about 1/2 the Weight and size of the 2.5 kW loads
- Rugged load for high power base station RF testing up to 2 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation up to 1500W full rated power.
- Similar to item shown except with 1-5/8 EIA Flange Connector.
- Simple but rugged design minimizes maintenance requirements.
The Model 8862 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically nonreflective termination for testing and adjusting transmitters under nonradiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2 GHz. Used in Good Condition
Product Specifications:
- Ambient Temperature Range: -40°C to +45°C
- Connector: 1-5/8' EIA Flange
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1GHz to 2 GHz at 1.25 max.
- Load Coolant: 1.5 gal. (5.68 liters) silcone oil
- Nominal Size: 17 1/8" L x 7 1/2" W x 13 1/8" H, (445 mm x 184 mm x 333 mm)
- Operating Position: Horizontal only
- Power Rating: 1500 W continuous
- Weight: 30 lbs. (12.6 kg)
Used or select New below.
Operating Manual and Specifications
|
|
|
|
| |
|
Bird 8861 Termaline RF Load 1 5/8 EIA Unflanged (New or Used) 1.5 KW 1500 Watts DC-2 GHz
8861 Termaline® RF Coaxial Termination
1-5/8" EIA, Unflanged
1500 Watts Oil-Cooled
Used in New condition, 90 day warranty
Compact, about 1/2 the Weight and size of the 2.5 kW loads
- Rugged load for high power base station RF testing up to 2 GHz.
- Oil-assisted (vented) convection cooling for safe, continuous operation up to 1500W full rated power.
- Similar to item shown except with 1-5/8 EIA Unflanged Connector.
- Simple but rugged design minimizes maintenance requirements.
The Model 8861 TERMALINE® Load Resistor is a self-contained high-power 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically nonreflective termination for testing and adjusting transmitters under nonradiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2 GHz. Used in New Condition
Product Specifications:
- Ambient Temperature Range: -40°C to +45°C
- Connector: 1-5/8' EIA Unflanged
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1GHz to 2 GHz at 1.25 max.
- Load Coolant: 1.5 gal. (5.68 liters) silcone oil
- Nominal Size: 17 1/8" L x 7 1/2" W x 13 1/8" H, (445 mm x 184 mm x 333 mm)
- Operating Position: Horizontal only
- Power Rating: 1500 W continuous
- Weight: 30 lbs. (12.6 kg)
Similar to item shown, connector is 1-5/8" EIA Unflanged.
Used or select New below.
Operating Manual and Specifications
|
|
|
|
| |
|
Bird 8431 Termaline RF Load (Dry) 600 Watts DC-2.5 GHz
The 8431 Dry Load has a power rating of 600W vertical or 500W horizontal, continuous.
- Frequency Range: dc to 2500MHz
- Impedance: 50 ohms nominal
- VSWR: 1.1 max. dc to 1000MHz
1.25 max. 1000 to 2500MHz
- Ambient Temperature Range: -40ºC to +45ºC
- Connector SQC Type N(F)
- Load Coolant: Dry. Convection air cooled
- Operating Position: Horizontal or Vertical
- Finish: Semi-Gloss black enamel
- Weight: 13.7 lbs
- Used in Almost New Condition
|
|
|
|
| |
|
Bird 8251T-230 Termaline RF Load 1 KW DC-2500 MHz 1 KW RF Load With Thermal Switch Option 230 Degree (New or Used)
8251T-230 Bird Termaline® RF Coaxial Termination
1 kW Continuous Duty, Oil-Cooled
Thermal Switch option 230 installed
1-5/8 Flange Fixed(M) Shown or N(F) or any QC
Used in new condition or New, select in options below.
- Rugged portable Bench load for high power base station RF testing up to 2.4 GHz.
- Oil-assisted convection cooling for safe, continuous operation up to 1000W full rated power.
- Connector 4240-096 1-5/8 inch EIA Fixed Flange (M), QC
- Or, can be shipped with LC or Type N(F) QC connector installed.
- Low-profile housing with handle and rubber feet for trouble-free operation in the most demanding environments.
- Ambient Temperature Range: -40°C to +45°C
- Connector: QC type (Female LC normally supplied, and Female N normally supplied unmounted)
- Finish: Gray powder coat
- Frequency Range and VSWR: DC to 1 GHz at 1.1 max, 1 GHz to 2 GHz at 1.25 max., 2 GHz to 2.4 at 1.3 max.
- Load Coolant: 1.1 gal. (4.1 liters) silicon oil
- Nominal Size: 17 29/32" L x 8 1/2" H x 5 15/16" W, (455 mm x 216 mm x 151 mm)
- Operating Position: Horizontal only
- Power Rating: 1000 W continuous
- Weight: 25 lbs, 8 oz. (11.5 kg)
The Model 8251 TERMALINE® Load Resistor is a portable, self-contained general purpose 50 ohm coaxial transmission line termination requiring no outside power source or additional equipment. It provides accurate, dependable, and practically non-reflective termination for testing and adjusting transmitters under non-radiating conditions. The load consists essentially of a cylindrical film type resistor immersed in a dielectric coolant. The resistor, individually selected for its accuracy, is enclosed in a special tapered housing which provides a linear reduction in surge impedance directly proportional to the distance along the resistor. This produces the uniform, practically reflectionless line termination from dc to 2.4 GHz. Select New Or Used Below.